Detail BW Gas Alert Micro 5 Multi-Gas Detector

Protect yourself Simultaneously monitor and display up to fi ve atmospheric hazards with the GasAlertMicro 5. Adaptable to a variety of applications, the GasAlertMicro 5 has an extensive selection of user-settable fi eld options and is available as either a standard toxic gas model, a PID model for the detection VOCs, or an IR model for CO2 detection. Use the passcode function to prevent unauthorized modifi cations of the instrument’ s settings. Compatible with BW’ s MicroDock II automatic test and calibration system, the GasAlertMicro 5 is unparalleled in its versatility, performance and overall value. Spesifikasi ; Gas Measuring range Resolution TWA STEL LOW HIGH O2 0-30.0% 0.1 N/ A N/ A 19.5 22.5 CO 0-999 ppm 1 35 200 35 200 H2S 0-100 ppm 1 10 15 10 15 PH3 0-5.0 ppm 0.1 0.3 1.0 0.3 1.0 SO2 0-100 ppm 0.1 2 5 2 5 NO2 0-99.9 ppm 0.1 2.0 5.0 2.0 5.0 HCN 0-30.0 ppm 0.1 4.7 10.0 4.7 10.0 Cl2 0-50.0 ppm 0.1 0.5 1.0 0.5 1.0 NH3 0-100 ppm 1 25 35 25 50 ClO2 0-1 ppm 0.1 0.1 0.3 0.1 0.3 O3 0-1 ppm 0.1 0.1 0.1 0.1 0.1 PID 0-999 ppm 5.0 50 100 50 100 LEL 0-100% LEL 0-5% v/ v 1% N/ A N/ A 10% 20% Auto zero: Yes Calibration: Automatic Backlight: Standard Mode: low light ( auto) ; alarm condition ( auto) ; reactivation on demand Alarm Only Mode: alarm condition ( auto) ; reactivation on demand Stealth Mode: backlight inactive; audible and visual alarms silenced Full function self-test: Sensor integrity, circuitry and battery; audible/ visual alarms Sensor: Plug-in, electrochemical cell ( toxic and oxygen) ; catalytic ( LEL) User field options: Confidence beep, pass code protection, latching alarms, passed calibration user- lockout option, “ SAFE” display function, stealth mode, oxygen auto-cal on start-up, alarm only backlight mode, combustible gas measurement ( % LEL or % by volume methane) , LCD language option, STEL calculation choice, TWA calculation choice ALARM INDICATORS: combustible correction factor options, user-settable calibration gas levelClearly advises alarm conditions with audible, visual and vibrator alarms Visual alarms: Two flashing alarm bars visible from all angles LCD indicates gas present and alarm levels encountered Audible alarm: Typically 95 dB at 1 ft./ 30 cm variable pulsed audible alarm Vibrator alarm: Pulses warning in gas alarm conditions, or for any status alarms Other: ALARMLEVELS: Low battery, over range, multiple gas / pump and failed or missing sensor Instantaneous Low Alarm for all gases; Instantaneous High Alarm for all gases; LCD: TWA ( time weighted average) and STEL ( short term exposure limit) for toxics Continuous, alphanumeric gas readout and status display advises Gases monitored: H2S, CO, O2, SO2, PH3, NO2, NH3, HCN, Cl2, ClO2, O3, PID and/ or combustibles ( 0-100% LEL or 0-5.0% methane) Gas concentration: Simultaneously and continuously displays gas concentration( s) for all sensors ( in ppm, % LEL, or % v/ v) STEL/ TWA ppm or % : Records STEL and TWA exposures and displays on demand Peak ppm or % : Records and displays peak exposure to gas and displays on demand Alarm setpoints: Displayed on activation Calibration due date: In days remaining Clock: Real-time clock setting displayed on start-up ( datalogger models only) TESTS: Full function self-test: Full function self-test on activation Battery: Continuous GENERAL SPECIFICATIONS: Rugged, composite material; two-shot molded polymer case with integral anti-shock boot Operating temperature: -4 to 122 oF / -20 to 50 oC Humidity: 0 - 95% RH ( non-condensing) EMI/ RFI: Complies with EMC Directive 89/ 336/ EEC Protection: Highly water resistant and dust proof housing Battery Options: 14 hrs on three AA alkaline cells ( 10 hours with optional motorized pump* ) 14 hrs on three AA alkaline cells ( 10 hours with optional motorized pump* ) 18 hrs on rechargeable “ hot-swappable” battery pack ( 13 hrs with optional motorized pump* ) * when equipped with oxygen, combustible, TwinTox and one additional toxic sensor 3 hours charge time. Size: 5.7 x 2.9 x 1.5 in. / 14.5 x 7.4 x 3.8 cm Weight: 13.1 oz. / 370 g WARRANTY: Full 2-year warranty including all sensors DATALOGGER OPTIONS: User-downloadable datalogger Data recorder: ll events and occurrences ( calibration zero adjustment, calibration span adjustment, gas readings, TWA, STEL, alarm condition, failures detected by the microprocessor) Sampling rate: Factory set at 5-second intervals and user-settable from 1 to 127-second intervals Storage: 2 months of continuous data via 32 MB Flash MMC card ( 64 MB and 128 MB cards also available) ; when full, the wrap-around feature replaces oldest data with most recent data
Tampilkan Lebih Banyak
cv. andalan prima sejahtera
cv. andalan prima sejahtera

CV. ANDALAN PRIMA SEJAHTERA

PREMIUM GOLD 10 Tahun
Jl. Muhtar Tabrani Perum Bintang Metropol Blok A-7/16 Bekasi Utara, bekasi - Indonesia
Indonesia 17122
bekasi - Indonesia
17 / 10 / 2019
Hubungi Kami

Detail BW Gas Alert Micro 5 Multi-Gas Detector

Protect yourself Simultaneously monitor and display up to fi ve atmospheric hazards with the GasAlertMicro 5. Adaptable to a variety of applications, the GasAlertMicro 5 has an extensive selection of user-settable fi eld options and is available as either a standard toxic gas model, a PID model for the detection VOCs, or an IR model for CO2 detection. Use the passcode function to prevent unauthorized modifi cations of the instrument’ s settings. Compatible with BW’ s MicroDock II automatic test and calibration system, the GasAlertMicro 5 is unparalleled in its versatility, performance and overall value. Spesifikasi ; Gas Measuring range Resolution TWA STEL LOW HIGH O2 0-30.0% 0.1 N/ A N/ A 19.5 22.5 CO 0-999 ppm 1 35 200 35 200 H2S 0-100 ppm 1 10 15 10 15 PH3 0-5.0 ppm 0.1 0.3 1.0 0.3 1.0 SO2 0-100 ppm 0.1 2 5 2 5 NO2 0-99.9 ppm 0.1 2.0 5.0 2.0 5.0 HCN 0-30.0 ppm 0.1 4.7 10.0 4.7 10.0 Cl2 0-50.0 ppm 0.1 0.5 1.0 0.5 1.0 NH3 0-100 ppm 1 25 35 25 50 ClO2 0-1 ppm 0.1 0.1 0.3 0.1 0.3 O3 0-1 ppm 0.1 0.1 0.1 0.1 0.1 PID 0-999 ppm 5.0 50 100 50 100 LEL 0-100% LEL 0-5% v/ v 1% N/ A N/ A 10% 20% Auto zero: Yes Calibration: Automatic Backlight: Standard Mode: low light ( auto) ; alarm condition ( auto) ; reactivation on demand Alarm Only Mode: alarm condition ( auto) ; reactivation on demand Stealth Mode: backlight inactive; audible and visual alarms silenced Full function self-test: Sensor integrity, circuitry and battery; audible/ visual alarms Sensor: Plug-in, electrochemical cell ( toxic and oxygen) ; catalytic ( LEL) User field options: Confidence beep, pass code protection, latching alarms, passed calibration user- lockout option, “ SAFE” display function, stealth mode, oxygen auto-cal on start-up, alarm only backlight mode, combustible gas measurement ( % LEL or % by volume methane) , LCD language option, STEL calculation choice, TWA calculation choice ALARM INDICATORS: combustible correction factor options, user-settable calibration gas levelClearly advises alarm conditions with audible, visual and vibrator alarms Visual alarms: Two flashing alarm bars visible from all angles LCD indicates gas present and alarm levels encountered Audible alarm: Typically 95 dB at 1 ft./ 30 cm variable pulsed audible alarm Vibrator alarm: Pulses warning in gas alarm conditions, or for any status alarms Other: ALARMLEVELS: Low battery, over range, multiple gas / pump and failed or missing sensor Instantaneous Low Alarm for all gases; Instantaneous High Alarm for all gases; LCD: TWA ( time weighted average) and STEL ( short term exposure limit) for toxics Continuous, alphanumeric gas readout and status display advises Gases monitored: H2S, CO, O2, SO2, PH3, NO2, NH3, HCN, Cl2, ClO2, O3, PID and/ or combustibles ( 0-100% LEL or 0-5.0% methane) Gas concentration: Simultaneously and continuously displays gas concentration( s) for all sensors ( in ppm, % LEL, or % v/ v) STEL/ TWA ppm or % : Records STEL and TWA exposures and displays on demand Peak ppm or % : Records and displays peak exposure to gas and displays on demand Alarm setpoints: Displayed on activation Calibration due date: In days remaining Clock: Real-time clock setting displayed on start-up ( datalogger models only) TESTS: Full function self-test: Full function self-test on activation Battery: Continuous GENERAL SPECIFICATIONS: Rugged, composite material; two-shot molded polymer case with integral anti-shock boot Operating temperature: -4 to 122 oF / -20 to 50 oC Humidity: 0 - 95% RH ( non-condensing) EMI/ RFI: Complies with EMC Directive 89/ 336/ EEC Protection: Highly water resistant and dust proof housing Battery Options: 14 hrs on three AA alkaline cells ( 10 hours with optional motorized pump* ) 14 hrs on three AA alkaline cells ( 10 hours with optional motorized pump* ) 18 hrs on rechargeable “ hot-swappable” battery pack ( 13 hrs with optional motorized pump* ) * when equipped with oxygen, combustible, TwinTox and one additional toxic sensor 3 hours charge time. Size: 5.7 x 2.9 x 1.5 in. / 14.5 x 7.4 x 3.8 cm Weight: 13.1 oz. / 370 g WARRANTY: Full 2-year warranty including all sensors DATALOGGER OPTIONS: User-downloadable datalogger Data recorder: ll events and occurrences ( calibration zero adjustment, calibration span adjustment, gas readings, TWA, STEL, alarm condition, failures detected by the microprocessor) Sampling rate: Factory set at 5-second intervals and user-settable from 1 to 127-second intervals Storage: 2 months of continuous data via 32 MB Flash MMC card ( 64 MB and 128 MB cards also available) ; when full, the wrap-around feature replaces oldest data with most recent data
Tampilkan Lebih Banyak