1
Hi, Guest!

  LOKASI :  bekasi - Indonesia

  AKTIVITAS :  43 minutes ago

BAGIKAN :   

Bagikan :
Masukan Data Diri Anda
Nama harus diisi !
Email harus diisi !
Format email harus [email protected] !
CV. ANDALAN PRIMA SEJAHTERA

E8500 Portable Industrial Combustion Gas & Emissions Analyzer

Update Terakhir
:
30 / 08 / 2019
Min. Pembelian
:
1 Unit
Harga
CALL
Bagikan
:
Air & Gas Analysis
Analyzer Disposable
Anemometer
Apparel
Autoclave (Sterilizer)
Bags
Balance
Ball Mills
Baths
Beakers
Bottles
Burets
Burners
Carts
Centrifuge
Chemical
Clamps and Support
Cleaning
Clinical
Climate Chamber
Color Measurement
Conductivity
Container
Crucibles
Cryogenics
Cylinders

Detail E8500 Portable Industrial Combustion Gas & Emissions Analyzer

E8500 Portable Industrial Gas Analyzer Selection Guide The E8500 is the most powerful and advanced portable gas analyzer on the market, and is a complete, portable tool for EPA complianceï ¿ ½ level emissions monitoring. Up to 9 Gas Sensors: O2, CO, NO, NO2, SO2, H2S ( Electrochemical) CO2, CxHy, High CO ( NDIR) Low NOx and ï ¿ ½ Trueï ¿ ½ NOx Measurements Builtï ¿ ½ in Thermoelectric Chiller with Automatic Condensate Removal Wireless Remote Printer Draft & Differential Pressure Measurement Two Channel Thermometer ( for stack gas & air temperature) Software for Realï ¿ ½ Time Data Logging, Graphing, and Reporting Wireless Communications with Computer & other Windows Devices CO Dilution Autoï ¿ ½ Range for Measurements up to 20, 000ppm Longï ¿ ½ Term Monitoring and Data Logging with Internal Memory Gas Velocity Measurements with Pitot Tube CO2% , Efficiency, & Excess Air Calculations Rotating LCD Display Light Weight, Durable, & Easy to Transport Design E8500 Ordering Code Table A - Electrochemical Sensors O O2 Sensor ( 0 - 25 % ) C CO Sensor ( 0 - 8000 ppm) with Dilution Auto-Range up to 20, 000 ppm N NO Sensor ( 0 - 4000 ppm) D NO2 Sensor ( 0 - 1000 ppm) S SO2 Sensor ( 0 - 4000 ppm) H H2S Sensor ( 0 - 500 ppm) P: 215-750-1212 F: 215-750-1399 A: 172 Middletown Blvd, Ste B201 Langhorne, PA 19047 E Instruments International www.E-Inst.com Part # 8500 - Table A - Table B- Table C Table B - NDIR ( non-dispersive infrared) Sensors ABC CO2 Sensor ( 0 - 20 % ) , CxHy Sensor ( 0 - 3 % ) , and High CO Sensor ( 0 - 15 % ) 0 No NDIR sensors Table C - Sampling Probes and Hoses 12 12ï ¿ ½ ( 300mm) Probe, 1470F ( 800C) max, with 10ï ¿ ½ ( 3m) Dual Hose 30 30ï ¿ ½ ( 750mm) Probe, 1470F ( 800C) max, with 10ï ¿ ½ ( 3m) Dual Hose 40HT 40ï ¿ ½ ( 1m) Probe, 2190F ( 1200C) max, with 10ï ¿ ½ ( 3m) Hose for High Temperature Combustion Applications 60HT 60ï ¿ ½ ( 1.5m) Probe, 2190F ( 1200C) max, with 10ï ¿ ½ ( 3m) Hose for High Temperature Combustion Applications
Tampilkan Lebih Banyak
cv. andalan prima sejahtera
cv. andalan prima sejahtera

CV. ANDALAN PRIMA SEJAHTERA

PREMIUM GOLD 10 Tahun
Jl. Muhtar Tabrani Perum Bintang Metropol Blok A-7/16 Bekasi Utara, bekasi - Indonesia
Indonesia 17122
bekasi - Indonesia
22 / 08 / 2019
Hubungi Kami

Detail E8500 Portable Industrial Combustion Gas & Emissions Analyzer

E8500 Portable Industrial Gas Analyzer Selection Guide The E8500 is the most powerful and advanced portable gas analyzer on the market, and is a complete, portable tool for EPA complianceï ¿ ½ level emissions monitoring. Up to 9 Gas Sensors: O2, CO, NO, NO2, SO2, H2S ( Electrochemical) CO2, CxHy, High CO ( NDIR) Low NOx and ï ¿ ½ Trueï ¿ ½ NOx Measurements Builtï ¿ ½ in Thermoelectric Chiller with Automatic Condensate Removal Wireless Remote Printer Draft & Differential Pressure Measurement Two Channel Thermometer ( for stack gas & air temperature) Software for Realï ¿ ½ Time Data Logging, Graphing, and Reporting Wireless Communications with Computer & other Windows Devices CO Dilution Autoï ¿ ½ Range for Measurements up to 20, 000ppm Longï ¿ ½ Term Monitoring and Data Logging with Internal Memory Gas Velocity Measurements with Pitot Tube CO2% , Efficiency, & Excess Air Calculations Rotating LCD Display Light Weight, Durable, & Easy to Transport Design E8500 Ordering Code Table A - Electrochemical Sensors O O2 Sensor ( 0 - 25 % ) C CO Sensor ( 0 - 8000 ppm) with Dilution Auto-Range up to 20, 000 ppm N NO Sensor ( 0 - 4000 ppm) D NO2 Sensor ( 0 - 1000 ppm) S SO2 Sensor ( 0 - 4000 ppm) H H2S Sensor ( 0 - 500 ppm) P: 215-750-1212 F: 215-750-1399 A: 172 Middletown Blvd, Ste B201 Langhorne, PA 19047 E Instruments International www.E-Inst.com Part # 8500 - Table A - Table B- Table C Table B - NDIR ( non-dispersive infrared) Sensors ABC CO2 Sensor ( 0 - 20 % ) , CxHy Sensor ( 0 - 3 % ) , and High CO Sensor ( 0 - 15 % ) 0 No NDIR sensors Table C - Sampling Probes and Hoses 12 12ï ¿ ½ ( 300mm) Probe, 1470F ( 800C) max, with 10ï ¿ ½ ( 3m) Dual Hose 30 30ï ¿ ½ ( 750mm) Probe, 1470F ( 800C) max, with 10ï ¿ ½ ( 3m) Dual Hose 40HT 40ï ¿ ½ ( 1m) Probe, 2190F ( 1200C) max, with 10ï ¿ ½ ( 3m) Hose for High Temperature Combustion Applications 60HT 60ï ¿ ½ ( 1.5m) Probe, 2190F ( 1200C) max, with 10ï ¿ ½ ( 3m) Hose for High Temperature Combustion Applications
Tampilkan Lebih Banyak