1
Hi, Guest!

  LOKASI :  bekasi - Indonesia

  AKTIVITAS :  17/10/2019

BAGIKAN :   

Bagikan :
Masukan Data Diri Anda
Nama harus diisi !
Email harus diisi !
Format email harus [email protected] !
CV. ANDALAN PRIMA SEJAHTERA

Jenco Conductivity, TDS, Temperature In-line Analyzer 6308CT

Update Terakhir
:
30 / 08 / 2019
Min. Pembelian
:
1 Unit
Harga
CALL
Bagikan
:
Air & Gas Analysis
Analyzer Disposable
Anemometer
Apparel
Autoclave (Sterilizer)
Bags
Balance
Ball Mills
Baths
Beakers
Bottles
Burets
Burners
Carts
Centrifuge
Chemical
Clamps and Support
Cleaning
Clinical
Climate Chamber
Color Measurement
Conductivity
Container
Crucibles
Cryogenics
Cylinders

Detail Jenco Conductivity, TDS, Temperature In-line Analyzer 6308CT

Description Conductivity analyzer, 1/ 4 DIN panel mount single parameter analyzer with an IP-65 case, and selectable 2 or 4- wire cells. Has programmable reference temperature and coefficients. The 4-20 mA output is fully programmable, reversible and isolated. There are 2 programmable relays for conductivity and one relay for temperature and an RS-485 interface. Password & ID protected. Graphical display. CE approved. 115/ 230V AC. Bumpless calibration CE approved RS-485 output Programmable relays for conductivity Reversible and isolated 4 to 20ma output Programmable relay for temperature Conductivity/ temp.measurement & control Simultaneous analysis and display for measurement and controls User programmable reference temperature temperature coefficient Selectable 2-wire or 4-wire cells for long cable length & wide measurement range Specifications Range Resolution Accuracy Cond. 0 uS to 5.0 mS 0.01 uS to 0.1 mS 0.5% ± 1 LSD TDS 0 ppm to 150.0 ppt 0.01 ppm to 0.1 ppt 0.5 % ± 1 LSD Temp. -10.0 to 120° C 0.1 ° C ± 0.1 ° C Conductivity Reference temperature: 1.5 ° C to 25.0 ° C Temperature coefficient: 0.0 % to 40.0% Basic cell constant: 0.01, 1 and 10.0 Cell constant range: ± 30% of basic cell constant Output Relays Output relays numbers: Two programmable high or low relays for conductivity Control type: On/ off Relay output ( resistive load only) : 5amps at 115 VAC, 2.5 amps at 230 VAC Relay set point hysteresis: User programmable Current Output Current output: Isolated 4 to 20 mA Range: Selectable zero, & span Accuracy: ± 0.02mA Isolated voltage: 500 VDC Maximum load: 500 ohms General ATC sensor: Thermistor 10kiloohms at 25 ° C Security protection: 4digit password Keypad: Audio feedback Communication: RS-485 Display: Graphic LCD w/ backlight Power source: 115/ 230 VAC, 50/ 60hz Dimensions: 1/ 4 DIN, depth 148 mm Weight: 950 gm
Tampilkan Lebih Banyak
cv. andalan prima sejahtera
cv. andalan prima sejahtera

CV. ANDALAN PRIMA SEJAHTERA

PREMIUM GOLD 10 Tahun
Jl. Muhtar Tabrani Perum Bintang Metropol Blok A-7/16 Bekasi Utara, bekasi - Indonesia
Indonesia 17122
bekasi - Indonesia
17 / 10 / 2019
Hubungi Kami

Detail Jenco Conductivity, TDS, Temperature In-line Analyzer 6308CT

Description Conductivity analyzer, 1/ 4 DIN panel mount single parameter analyzer with an IP-65 case, and selectable 2 or 4- wire cells. Has programmable reference temperature and coefficients. The 4-20 mA output is fully programmable, reversible and isolated. There are 2 programmable relays for conductivity and one relay for temperature and an RS-485 interface. Password & ID protected. Graphical display. CE approved. 115/ 230V AC. Bumpless calibration CE approved RS-485 output Programmable relays for conductivity Reversible and isolated 4 to 20ma output Programmable relay for temperature Conductivity/ temp.measurement & control Simultaneous analysis and display for measurement and controls User programmable reference temperature temperature coefficient Selectable 2-wire or 4-wire cells for long cable length & wide measurement range Specifications Range Resolution Accuracy Cond. 0 uS to 5.0 mS 0.01 uS to 0.1 mS 0.5% ± 1 LSD TDS 0 ppm to 150.0 ppt 0.01 ppm to 0.1 ppt 0.5 % ± 1 LSD Temp. -10.0 to 120° C 0.1 ° C ± 0.1 ° C Conductivity Reference temperature: 1.5 ° C to 25.0 ° C Temperature coefficient: 0.0 % to 40.0% Basic cell constant: 0.01, 1 and 10.0 Cell constant range: ± 30% of basic cell constant Output Relays Output relays numbers: Two programmable high or low relays for conductivity Control type: On/ off Relay output ( resistive load only) : 5amps at 115 VAC, 2.5 amps at 230 VAC Relay set point hysteresis: User programmable Current Output Current output: Isolated 4 to 20 mA Range: Selectable zero, & span Accuracy: ± 0.02mA Isolated voltage: 500 VDC Maximum load: 500 ohms General ATC sensor: Thermistor 10kiloohms at 25 ° C Security protection: 4digit password Keypad: Audio feedback Communication: RS-485 Display: Graphic LCD w/ backlight Power source: 115/ 230 VAC, 50/ 60hz Dimensions: 1/ 4 DIN, depth 148 mm Weight: 950 gm
Tampilkan Lebih Banyak