Detail WILKS InfraCal 2 ATR-E PERCENT ETHANOL IN GASOLINE PORTABLE

The InfraCal 2 Ethanol Blend Analyzer for measuring percent ethanol in gasoline is the ideal solution where a quick, accurate, on-site measurement is required and a single, repetitive ethanol blend analysis is needed.  The InfraCal 2 is based on proven IR technology, originally developed by Wilks, and used by regulatory agencies and fuel terminals worldwide.  The compact, easy-to-use InfraCal 2 has a measurement range of 0-100% ethanol in gasoline and an accuracy of +/- 0.2. These results are comparable to ASTM D4851.  

Samples are applied to a scratch-resistant zinc selenide attenuated total reflectance (ATR) sample plate and easily cleaned with a cloth or paper towel.  No solvents requiring special ventilation, expensive waste disposal or difficult to clean cells are needed. The analysis can be done by non-technical personnel with no formal training and is ideal for lab or field use. The InfraCal2 has added features such as touch screen display, data storage and transfer, a multi-language interface and password protected settings.  The internal battery pack allows for portability and up to 12 hours continuous use, providing results in under a minute at a fuel loading rack, in a laboratory or at a pump in a fueling station.

  • Measurement range: 0 - 100% ethanol
  • Instrument repeatability: +/- 0.2
  • Compares to ASTM D4815

Features & Benefits

  Benefits

  Features

Internal Data Storage 

Data storage including each measurement tagged with analyst, location and date/time information, and password protected instrument settings

Export

Directly to your PC via USB or a Flash Drive

Touch Screen Display

The touch screen display allows a simple set up for quick operation along with an easy calibration wizard.

Internal Battery

The internal battery pack allows for portability and up to 12 hours continuous use.
Multi-Language Interface

English, Spanish, French, Arabic

Password Protected Settings

Calibration and data are password protected to avoid accidental deletion

Multiple Calibrations

A Multitude of calibrations can be stored allowing the InfraCal to be moved to different locations without the need to recalibrate after initial calibration at a particular location

No need for Installation/Commissioning

The InfraCal 2 is a portable analyzer, weighing less than 5 lbs. with a 6 in. square foot print, requiring no installation or commissioning, little to no routine maintenance or recalibration.

Minimal Consumables

The analysis requires little to no consumables making the cost-per-test minimal.
 

 


Highlights

The InfraCal 2 Model ATR-E can be ordered with a choice of one of both of the following factory calibrations. The two ranges of calibration available are 0-20% and 70-100%. A 0-20% 5 Point Ethanol Low Concentration Calibration includes0, 5, 10, 15, and 20% ethanol in gasoline points. A 70-100% 5 Point Ethanol High Concentration Calibration includes 70, 80, 90, 95, and 100% ethanol in gasoline. The calibration is performed using standards prepared by a certified laboratory.  

Specifications: 

Instrument Type

Fixed Filter Infrared Analyzer

Analytical Wavelength/Wave Number

9.6 µm, 1045cm-1

Power Requirements

18 volts DC, 3.3 amps, internal battery pack available

Power Supply

Universal AC/DC provided

Weight

5.8 lb. (2.6 kg) with battery -7.0 lbs (3.2 kg)

Dimensions

(17 cm) x 7.8" (19.8 cm) x 5.2" (13.2 cm)

Suggested Operating Range

5°C - 40°C

Typical Useful Measurement Range

0 - 98% Ethanol in Gasoline

Analysis Time

Less than 30 seconds

Instrument Repeatability

0 - 20%±0.2%, 20 - 98%±1% of ethanol in petrol concentration

Communication Port

USB, RS 232

 
Tampilkan Lebih Banyak
cv. andalan prima sejahtera
cv. andalan prima sejahtera

CV. ANDALAN PRIMA SEJAHTERA

PREMIUM GOLD 10 Tahun
Jl. Muhtar Tabrani Perum Bintang Metropol Blok A-7/16 Bekasi Utara, bekasi - Indonesia
Indonesia 17122
bekasi - Indonesia
17 / 10 / 2019
Hubungi Kami

Detail WILKS InfraCal 2 ATR-E PERCENT ETHANOL IN GASOLINE PORTABLE

The InfraCal 2 Ethanol Blend Analyzer for measuring percent ethanol in gasoline is the ideal solution where a quick, accurate, on-site measurement is required and a single, repetitive ethanol blend analysis is needed.  The InfraCal 2 is based on proven IR technology, originally developed by Wilks, and used by regulatory agencies and fuel terminals worldwide.  The compact, easy-to-use InfraCal 2 has a measurement range of 0-100% ethanol in gasoline and an accuracy of +/- 0.2. These results are comparable to ASTM D4851.  

Samples are applied to a scratch-resistant zinc selenide attenuated total reflectance (ATR) sample plate and easily cleaned with a cloth or paper towel.  No solvents requiring special ventilation, expensive waste disposal or difficult to clean cells are needed. The analysis can be done by non-technical personnel with no formal training and is ideal for lab or field use. The InfraCal2 has added features such as touch screen display, data storage and transfer, a multi-language interface and password protected settings.  The internal battery pack allows for portability and up to 12 hours continuous use, providing results in under a minute at a fuel loading rack, in a laboratory or at a pump in a fueling station.

  • Measurement range: 0 - 100% ethanol
  • Instrument repeatability: +/- 0.2
  • Compares to ASTM D4815

Features & Benefits

  Benefits

  Features

Internal Data Storage 

Data storage including each measurement tagged with analyst, location and date/time information, and password protected instrument settings

Export

Directly to your PC via USB or a Flash Drive

Touch Screen Display

The touch screen display allows a simple set up for quick operation along with an easy calibration wizard.

Internal Battery

The internal battery pack allows for portability and up to 12 hours continuous use.
Multi-Language Interface

English, Spanish, French, Arabic

Password Protected Settings

Calibration and data are password protected to avoid accidental deletion

Multiple Calibrations

A Multitude of calibrations can be stored allowing the InfraCal to be moved to different locations without the need to recalibrate after initial calibration at a particular location

No need for Installation/Commissioning

The InfraCal 2 is a portable analyzer, weighing less than 5 lbs. with a 6 in. square foot print, requiring no installation or commissioning, little to no routine maintenance or recalibration.

Minimal Consumables

The analysis requires little to no consumables making the cost-per-test minimal.
 

 


Highlights

The InfraCal 2 Model ATR-E can be ordered with a choice of one of both of the following factory calibrations. The two ranges of calibration available are 0-20% and 70-100%. A 0-20% 5 Point Ethanol Low Concentration Calibration includes0, 5, 10, 15, and 20% ethanol in gasoline points. A 70-100% 5 Point Ethanol High Concentration Calibration includes 70, 80, 90, 95, and 100% ethanol in gasoline. The calibration is performed using standards prepared by a certified laboratory.  

Specifications: 

Instrument Type

Fixed Filter Infrared Analyzer

Analytical Wavelength/Wave Number

9.6 µm, 1045cm-1

Power Requirements

18 volts DC, 3.3 amps, internal battery pack available

Power Supply

Universal AC/DC provided

Weight

5.8 lb. (2.6 kg) with battery -7.0 lbs (3.2 kg)

Dimensions

(17 cm) x 7.8" (19.8 cm) x 5.2" (13.2 cm)

Suggested Operating Range

5°C - 40°C

Typical Useful Measurement Range

0 - 98% Ethanol in Gasoline

Analysis Time

Less than 30 seconds

Instrument Repeatability

0 - 20%±0.2%, 20 - 98%±1% of ethanol in petrol concentration

Communication Port

USB, RS 232

 